Biochrom 30+ Series of Amino Acid Analyzers
Biochrom 30+ Amino Acid Analyzer Physiological System
Biochrom launches the Biochrom 30+ Series of amino acid analyzers -the gold standard in dedicated amino acid analysis. Clinical laboratories worldwide trust this well documented classical amino acid analysis method based on ion exchange with post column derivitization with Ninhydrin.This allows both qualitative and quantitative analysis of up to 56 amino acids and derivatives, including Argininosuccinic acid, Alloisoleucine and Sulfocysteine.
The Biochrom 30+ Physiological system uses a combination of 5 lithium citrate buffers to achieve a full amino acid profile in less than 90 minutes using the new Accelerated method.
- Metabolic screening and clinical research on plasma, urine or CSF in Metabolic, Clinical biochemistry and Pedriatric labs in hospitals, contract analysis labs and other clinical institutions
- Clinical research in Universities and veterinary labs.
- QC and composition analysis in bioscience and pharmaceutical companies
Specific applications
• Detection and monitoring of metabolic disease and inborn
errors of metabolism (IEM), such as PKU and MSUD and other
aminoacidopathies in urine, plasma and CSF.
• Protein and peptide analysis for pharmaceutical
applications.
• Food, beverages, plant extracts, fermentation products, culture
media, nutraceuticals and infusion fluids
A Dedicated Amino Acid Analysis System
Accurate: Superb separation accurately
identifies and quantifies free amino acids, as well as the amino
acid composition of proteins and peptides.
Reliable: Minimal matrix interference and near
baseline separation helps to reduce ambiguities in interpretation
and increase confidence in diagnosis of inborn errors of
metabolism. Automated derivatization of amino acids maximizes
reproducibility.
Fast: Rapid protocols that increase sample
throughput by cutting analysis time.
Economical: The column cleaning and repacking
service, gives columns an almost indefinite life and cuts the cost
of ownership.
Fully Automated: Total PC control allows 24/7
operations.
Versatile: Wide variety of sample types
compatible: Urine, plasma, serum, CSF, amniotic fluid, culture
media, tissue extracts, protein hydrolysates from various food and
feedstuff samples or synthetic drugs, nutraceuticals,
beverages.
Easy to implement: No lengthy
method development required as this well characterized system is
established worldwide. All customers have their instrument
optimised to their application directly from the factory.
Convenient: Interchangeable sample trays allow
samples to be prepared in advance and stored refrigerated.
Robust: Advanced fluidics and
robust hardware mean easy maintenance for users, backed by the
reassurance of Biochrom's dedicated service and support team.
Flexible: Integrated software, choice of different
methods to adapt to the user's needs. Automatic sample set-up.
Networking and exporting of data.
Compact: Bench top design requiring minimum lab
space.
3 full screening methods are available that you can choose
according to your business needs:
| Order Code | System | Use | Minutes (to Arginine) |
| 80-6000-50 | Biochrom 30+ Physiological Accelerated System | When speed is a decisive factor, with little compromise on the peak resolution | 90min |
| 80-6000-53 | Biochrom 30+ Physiological High Performance System |
The best compromise between speed, resolution and column life | 125min |
| 80-6000-56 | Biochrom 30+ Physiological High Resolution System |
When 100% baseline separation and a maximum number of amino acid separated are required. Ideal for Research and low sample throughputs | 150min |
For a Chromatogram of the accelerated method download the new datasheet below.
Why you need a dedicated instrument for amino acid
analysis?
The diagnosis and treatment of various disorders are greatly
advanced using a dedicated amino acid analyzer. The difficulty of
analyzing amino acids with conventional HPLC systems is mainly due
to the complex nature of the samples and the unique chemical
properties of the amino acids (ionic compounds with no specific
absorption wavelength). A dedicated system is the most reliable
solution for consistent and reproducible results. Most of the
illnesses caused by inborn errors of metabolism (IEM) can be
identified by amino acid analysis of urine, cerebrospinal fluid and
blood plasma. Early detection in newborn infants allows necessary
treatment to be applied rapidly. Method development is not required
on a dedicated AAA as it has been already set up and extensively
tested so it can be used routinely 24/7 with little user
intervention.
Reliable rapid screening of large numbers of samples for specific
amino acids can be performed 24 hours per day using short methods
e.g. for PKU and MSUD disorders.
Biochrom has a large number of clinical users worldwide ranging
from research labs, children's hospitals and regional centres, to
large national reference laboratories.
Biochrom 30+ Physiological Systems
All include PC, cooled Autosampler and EZChrom Elite. Details of the Biochrom 30+ instrument package
Reagents:
-
80-2118-30 Ultra Ninhydrin Reagent Kit 2L
-
80-2117-77 Ultra Physiological Fluid Chemical Kit*